How to calibrate Xhorse Condor XC-Mini Plus automatic key cutting machine? This post is going to show the procedure in details.
Power on Condor XC-Mini Plus, press “Self Test” on main menu.
Step 1. Height Level Adjustment
To start this process, make sure the cutter is lower than the probe. Press “Height Level Adjustment”.
Reminder:
Press “Continue”, the cutter on XC-Mini Plus starts touching the clamp, you should lower the probe to be same height level. Press “Continue” again.
It will ask what type of cutter you’re using on Condor Mini Plus screen, today we are taking 2.5mm as example, so select “2.5mm”, then press “Confirm”.
Step 2. Clamp Calibration
Press “Clamp Calibration”, select the clamp type you’re using: M1/M2. Today we are using an M1 clamp, so select M1.
Reminder:
Press “Continue”, XC-Mini Plus starts calibrating…
Calibrate OK, press “Confirm” to return.
Step 3. Cutting Calibration
Return back to upper level, press “Cutting Calibration”.
Reminder:
Press “Continue”, Xhorse condor starts cutting…
Completed!
You are now set to use the Condor XC-Mini Plus key cutting machine.
https://www.vvdishop.com/service/xhorse-condor-xc-mini-plus-calibration.html